Three-phase meter N Series
With MID authentication for effect and reactive energy installation dimension 4TE
- Digital three-phase meter up to 80A direct measurement
- Digital three-phase transformer also for 5A
- Display of active and reactive energy, current active and reactive power (consumption and supply)
- Adjustable (unlimited changeable) converter ratio
- Double tariff meter HT/NT with tariff switching input
- S0-output for active and reactive energy
- Optional extension through communication modules
- Accuracy: active energy B (cl. 1), reactive energy A (cl. 2)
- Made in EU,with EU wide valid MID certification
- Communication modules mountable side by side (KNX, M-Bus, MOD-Bus, LAN, SD-Card, eVision)
Alternating current counter
with MID certification for active energy assembly dimension 1TE
- Electronic single-phase AC counter up to 32 A direct measurement
- Display of active energy and current active power (consumption and supply)
- Accuracy: Active energy B (cl. 1)
- 230V AC, 5(32)A, 50Hz
- S0 interface for active energy
- Made in the EU, with MID certification valid throughout the EU
- Communication modules mountable side by side (KNX, M-Bus, MOD-Bus, LAN, SD-Card, eVision)
Item | Item-No. | Width | Execution | kg/pc. |
KE-N/5 | 19 5550 | 4 TE | Transformer measurement | 0,3 |
KE-N80 | 19 5551 | 4 TE | Direct measurement | 0,4 |
KE-W32 M, Alternating current counter | 19 5651 | 1 TE | Direct measurement | 0,2 |
Communication modules |
M-bus module | 19 5580 | 1 TE | | 0,1 |
MOD-bus module RTU module | 19 5581 | 1 TE | | 0,1 |
LAN-bus gateway module | 19 5582 | 1 TE | | 0,1 |
KNX module | 19 5583 | 1 TE | | 0,1 |
SD card module (data logger) | 19 5584 | 1 TE | | 0,1 |
Power pack for SD card module | 19 5585 | 1 TE | | 0,1 |
eVision module with embedded web app | 19 5586 | 1 TE | | 0,1 |
LAN server Modbus/TCP data concentrator
Performance characteristics
All data can be transferred via LAN/WLAN/internet using an HTTP interface in a web browser.
- Device coupler via Modbus (RTU)
- Data is transferred globally using the TCP/IP protocol
- Maximum 31 measuring instruments via Modbus
- Two gigabytes of memory are installed
- Only 4 TE wide (72 mm)
Item | Item-No. | kg/pc. | Packaaging |
Modbus | 19 5701 | 0,31 | 1 |
Technical data
| | LAN server modbus / TCP |
---|
Memory | | 2 GB internal |
LAN HW interface | | RJ 45 |
LAN SW protocol | | TCP / IP |
LAN baud rate | | 10 / 100 Mbit/s |
Protocols at application level | | HTTP - FTP modbus / TCP |
Interface to instruments | | RS 485 |
HW interface | | 2-wire, shielded |
SW protocol | | Modbus RTU und ASCII |
Measuring instruments directly connectable | | 31 |
DIN housing units | | 4 |
According to general standards | | EN 60950 |
Data acc. to IEE 802.3 AS, IEC 60950 EN 61000-6-2, EN61000-4-2 | | yes |
Sortirajte kao
Prikaz po stranici
Number of pieces in the package 1
Number of pieces in the package 1
Number of pieces in the package 1
Number of pieces in the package 1
Number of pieces in the package 1
Number of pieces in the package 1